The 4 Physical Root Causes of Component Failure: The Basics (Part 1)

Maintenance & Reliability

The 4 Physical Root Causes of Component Failure: The Basics (Part 1)

Author: Bob Latino CEO at Reliability Center, Inc.

This article is directed at those ‘first responders’ who arrive immediately at the failure scene. These are the people who have to ensure the area is safe, preserve the scene for investigators and contribute to a plan to expedite a quick, safe return to production norms.

Many do not understand how valuable failed parts are to the metallurgical/forensic investigators. Broken parts are to metallurgists’, like the murder weapon is to a forensic crime investigator.

This article is meant to educate those that have access to the failed parts first, as to why they should preserve them in their failed state (not cleaning them up). We want to give them enough knowledge to be dangerous and raise their curiosity as to making a call on the fracture patterns they see.

Most all components fail for one, or a combination of, four (4) major physical reasons.

  1. Erosion
  2. Corrosion
  3. Fatigue
  4. Overload

In Part I of this mini-series, we will explore Erosion and Corrosion. We will save Fatigue and Overload for Part II (in an effort to make the learning more digestible in smaller chunks:-).

When investigating failures involving components, their fracture surfaces will tell a story as to what happened to them. As you approach any such failure scene, try and visualize being that failed part and thinking to yourself, “What just happened to me?” Visualize the part being in operation and the forces affecting it. Seems kind of corny, but it is a very effective approach to understanding of what happened. Let’s explore the basics of these very involved failure patterns.

Erosion: Erosion is caused by the presence of particles in the process medium contacting a surface and damaging it. Erosion can be delivered from fluid/air:

  • Fluid/air contaminated (particles present)
  • Fluid/air viscosity changed
  • Fluid/air velocity changed
  • Material eroding is wrong material for existing service
  • Materials are not compatible

Erosion can be abrasive or adhesive. Here are some basic examples:

Corrosion: Corrosion is the deterioration of a material due to interaction with its environment. It is the process in which metallic atoms leave the metal or form compounds in the presence of water and gases. Metal atoms are removed from a structural element until it fails, or oxides build up inside a pipe until it is plugged. Corrosion is an electro-chemical process. Corrosion can be complicated. To identify that there is corrosion should be sufficient for novices. Further detailed analysis should be performed by a qualified professional.

The are several types of corrosion, such as:

  • Uniform Attack
  • Pitting Corrosion Attack
  • Crevice Corrosion Attack
  • Galvanic Corrosion Attack
  • Erosion-Corrosion Attack
  • Stress Corrosion Cracking
  • Fretting Corrosion Attack

There are numerous variables that can create corrosion, here are some:

  • Contamination/impurities
  • Water quality
  • Aeration
  • Galvanic couples
  • Material selection
  • Effects of welding
  • Stagnation
  • Turbulence
  • Pressure
  • Deposits
  • Crevices
  • Startups and shutdowns

Here are some basic examples of each type of corrosion:

For the seasoned investigative veterans, this information will be old news (Investigation 101). However, the more the front-line folks in the field know these basics, the more they will be able to assist these veterans in their investigations. Proper investigations just cannot be comprehensive and thorough, without this physical evidence. So in the end, we are all helping out each other.

This will conclude Part I of our Component Failure Basics (2 of the 4 primary failure modes). We will address the last ones (Fatigue and Overload) in Part II.

Learn more about Why Parts Fail.

 

Below are some additional resources:

PROACT Lead Investigator Training – https://www.reliability.com/lead-investigator.html (2 weeks)

PROACT RCA Methodology Training – https://www.reliability.com/root-cause-analysis-training.html (3 Days)

PROACT Investigation Management System, Software Solutions – https://www.reliability.com/software.html (Desktop, Enterprise and Online)

 

Related Articles

Sulzer Cost effective sustainable fuel production

Cost effective sustainable fuel production

Benchmarking Market Report highlights cost-leadership of Sulzer Chemtech BioFlux Process Technology for Renewable Fuels production BioFlux® process technology for renewable fuel…

Related Whitepapers

Expansion Joint Expertise Improves Industrial Wastewater System Reliability

The majority of industries have wastewater treatment plants. Government agencies and local governments require these facilities to meet pretreatment requirements. Pretreatment rules were enacted to prevent…

How to Decrease Oil Changes with Bearing Isolators [Inforgraphic]

Learning how to decrease oil changes can be time- and money-saving. Oil life can be long if contamination is eliminated, which is easier said than…

Synchronous Machines Are The Optimal Choice For Heavy Industry

TECO-Westinghouse experience assures superior performance and reliability For over a century, Westinghouse has been the pacesetter in the design and production of electric machines for heavy…

Why FLEXXORs Are Designed Differently

J. Hilbert Anderson, President of Coupling Corporation of America, discusses some of the reasons why FLEXXORs are designed differently from all other flexible couplings, and…

Comments

One response to “The 4 Physical Root Causes of Component Failure: The Basics (Part 1)”

  1. M Rohan says:

    Hello,

    I m a maintenance executive in a manufacturing industry. I want to learn the RCA technique. Is this training course available online? Are there any webinars planned on RCA in coming months?

    Regards
    M Rohan, PMP
    +92 324 489 49 89

Leave a Reply

Your email address will not be published. Required fields are marked *

Join the #PumpTalk Community


By submitting this form, you are consenting to receive marketing emails from: Empowering Pumps & Equipment, 2205-C 7th Street, Tuscaloosa, AL, 35401, http://www.empoweringpumps.com. You can revoke your consent to receive emails at any time by using the SafeUnsubscribe® link, found at the bottom of every email. Emails are serviced by Constant Contact