Engineering & Design
Theory Bites Inducers

Theory Bites: Inducers/Cavitation– NPSHR

Theory bites are a collection of basic hydraulic theory and will touch upon pump design and other areas of pump industry knowledge.

Inducers are used in the event of the danger of cavitation. They increase the pressure in the inlet area of the impeller.

An inducer is the axial inlet portion (Axial Impeller, propeller) of a centrifugal pump, the function of which is to raise the inlet head by an amount sufficient to prevent significant cavitation in the following pump stage.

It is located immediately upstream of the pump impeller, before the first stage in Multistage Pumps.

It is used in applications in which the inlet pressure of a pump is close to the vapor pressure of the pumped liquid. The inducer’s role is to reduce the NPSHR. This is achieved by increasing the static pressure upstream of the impeller.

One of the things to take into account when using an inducer is that it reduces the operating range.

For more details check out, Cavitation and The Centrifugal Pump: A Guide For Pump Users (Edward Grist).

Read more Theory Bites!

Related Articles

Engineers Week 2023

Engineers Week 2023

Engineers play a pivotal role in our everyday lives and they deserve recognition. We are thankful to have many outlets…

Related Whitepapers

Expansion Joint Expertise Improves Industrial Wastewater System Reliability

The majority of industries have wastewater treatment plants. Government agencies and local governments require these facilities to meet pretreatment requirements. Pretreatment rules were enacted to prevent…

How to Decrease Oil Changes with Bearing Isolators [Inforgraphic]

Learning how to decrease oil changes can be time- and money-saving. Oil life can be long if contamination is eliminated, which is easier said than…

Synchronous Machines Are The Optimal Choice For Heavy Industry

TECO-Westinghouse experience assures superior performance and reliability For over a century, Westinghouse has been the pacesetter in the design and production of electric machines for heavy…

Why FLEXXORs Are Designed Differently

J. Hilbert Anderson, President of Coupling Corporation of America, discusses some of the reasons why FLEXXORs are designed differently from all other flexible couplings, and…

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *

Join the #PumpTalk Community


By submitting this form, you are consenting to receive marketing emails from: Empowering Pumps & Equipment, 2205-C 7th Street, Tuscaloosa, AL, 35401, http://www.empoweringpumps.com. You can revoke your consent to receive emails at any time by using the SafeUnsubscribe® link, found at the bottom of every email. Emails are serviced by Constant Contact