Check valves are used in a wide range of industrial processes. While selecting the correct check valve design and materials for your application is important, it can be equally important to pay attention to what differential pressure is required to open the check valve.

Spring-loaded check valves have a spring that is activated by the pressures in the media, which open and close the valve. In spring-loaded check valves the cracking pressure is determined by the spring setting and orientation of flow through the check valve. Swing check valves; however, use a flapper that swings off the seat to allow forward flow and then swings back to the seat when the flow is stopped (Learn more about the differences in spring-loaded check valves and swing check valves). With spring-loaded check valves, it may be possible for the spring (and the resulting net cracking pressure) to be tailored to the application. Typically, with swing check valves you are limited to the weight of the flapper or checking mechanism.

Spring loaded check valves can be built with springs to allow flow in any orientation while most swing checks are not suitable for flow vertical up or vertical down through the valve. Additionally, the use of a spring check valve minimizes water hammer.

Ultimately, if you need a check valve that will allow you to select the cracking pressure to meet the needs of your application, then a spring-loaded check valve is preferred.

What is Cracking Pressure?

Often measured in pounds per square inch (PSI), cracking pressure is the difference in pressure between the valve’s inlet and outlet ports. It’s the pressure differential required to “crack” open the valve (the point at which there is a sudden rise in flow). It’s also sometimes called the spring setting. If a cracking pressure is too high the valve will not fully open. If it is operating partially open the valve check mechanism may rattle and chatter, which can cause excessive wear and premature valve failure. This can result in the check mechanism failing to operate, coming apart with components traveling up or downstream (which can destroy valuable equipment), and preventing the function of stopping reverse flow.

Effects of Vertical Installation on the Cracking Pressure

Most spring-loaded check valves have a minimum recommended net cracking pressure; however, the cracking pressure is affected by vertical flow orientation. If the flow direction is vertical down, gravity pulls the weight of the trim components against the valve spring. This reduces the net cracking pressure, which may cause the valve to open or fail to return closed. In these cases, the spring selected must be heavy enough to support the weight of the trim, any column of liquid or media desired to be retained and achieve the minimum net cracking pressure. If you install a spring-loaded check valve in a vertical flow up orientation, then the weight of the trim components would increase the amount of force required to open the check valve. Your net cracking pressure will be the combination of the trim weight, the spring, and any fluid column above the check valve.

When you’re designing a system for automatic flow control the design of your check valve matters and the correct cracking pressure can be crucial. Working with a manufacturer that can tailor check valves to your application can be the difference between a low maintenance, properly functioning system, or one that requires frequent maintenance and sub-par performance. Most spring-loaded check valve manufacturers offer limited options for cracking pressures; however, Check-All Valve offers spring cracking pressures from 1/8 PSI to upwards of 85 PSI (and virtually anywhere in between). Check-All has a large selection of in-stock springs, and when those will not suffice the option is available to special order a setting of your choice. With this versatility there is a solution for nearly every application.

See Check-All’s entire product offering at:
www.checkall.com
References:
https://www.checkall.com/PDFfiles/Catalog.pdf

Related Articles

Check-All Foot Valve 101

Foot Valves 101

Foot valves are critical in preventing pump burn out. Similar to a check valve, foot valves are spring loaded and…

Related Whitepapers

Expansion Joint Expertise Improves Industrial Wastewater System Reliability

The majority of industries have wastewater treatment plants. Government agencies and local governments require these facilities to meet pretreatment requirements. Pretreatment rules were enacted to prevent…

How to Decrease Oil Changes with Bearing Isolators [Inforgraphic]

Learning how to decrease oil changes can be time- and money-saving. Oil life can be long if contamination is eliminated, which is easier said than…

Synchronous Machines Are The Optimal Choice For Heavy Industry

TECO-Westinghouse experience assures superior performance and reliability For over a century, Westinghouse has been the pacesetter in the design and production of electric machines for heavy…

Why FLEXXORs Are Designed Differently

J. Hilbert Anderson, President of Coupling Corporation of America, discusses some of the reasons why FLEXXORs are designed differently from all other flexible couplings, and…

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *

Join the #PumpTalk Community


By submitting this form, you are consenting to receive marketing emails from: Empowering Pumps & Equipment, 2205-C 7th Street, Tuscaloosa, AL, 35401, http://www.empoweringpumps.com. You can revoke your consent to receive emails at any time by using the SafeUnsubscribe® link, found at the bottom of every email. Emails are serviced by Constant Contact