Centrifugal Pump Minute: Troubleshooting: Excessive Seal Leakage

PSG

Centrifugal Pump Minute: Troubleshooting: Excessive Seal Leakage

By: PSG

During this Centrifugal Pump Minute, James Farley, Senior Director of Product Management for Griswold, discusses the conditions that could cause your centrifugal pump to experience excessive seal leakage and provides remedies to troubleshoot the problem.

You can also have excessive leaking through the steel chamber. This can happen to pumps operating in normal hydraulic conditions, the pumps are running and you’re getting the flow and head out of the pump, but you’re getting an excessive leak out of the steel.

If this is a packed pump you can look at adjusting your packing gland making sure that it is properly heightened so that you’re reducing the leak. You’re not going to stop a leak in packing but you can control it. Additionally, you need to make sure the packing is installed properly. And so you need to make sure that the packing rings are installed so that the slit is never aligned otherwise, you’re going to get excessive leaking through the packing and so you could recheck the packing.

If you’re dealing with more of a mechanical seal you can check to make sure that the shaft or the shaft sleeve has not been damaged. If there is a sweat score or nick on the shaft or the shaft sleeve where the mechanical steel fit, you may need to replace the shaft or the shaft sleeve so that the seal does not leak near the shaft. You could have a worn or damaged mechanical seal. There’s a whole slew of things that could contribute to a worn mechanical seal, but you may need to replace that and or look at the seal flush system to properly maintain the mechanical seal in the system.

Check out more Centrifugal Pump Minutes!

Related Articles

Related Whitepapers

Expansion Joint Expertise Improves Industrial Wastewater System Reliability

The majority of industries have wastewater treatment plants. Government agencies and local governments require these facilities to meet pretreatment requirements. Pretreatment rules were enacted to prevent…

How to Decrease Oil Changes with Bearing Isolators [Inforgraphic]

Learning how to decrease oil changes can be time- and money-saving. Oil life can be long if contamination is eliminated, which is easier said than…

Synchronous Machines Are The Optimal Choice For Heavy Industry

TECO-Westinghouse experience assures superior performance and reliability For over a century, Westinghouse has been the pacesetter in the design and production of electric machines for heavy…

Why FLEXXORs Are Designed Differently

J. Hilbert Anderson, President of Coupling Corporation of America, discusses some of the reasons why FLEXXORs are designed differently from all other flexible couplings, and…

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *

Join the #PumpTalk Community


By submitting this form, you are consenting to receive marketing emails from: Empowering Pumps & Equipment, 2205-C 7th Street, Tuscaloosa, AL, 35401, http://www.empoweringpumps.com. You can revoke your consent to receive emails at any time by using the SafeUnsubscribe® link, found at the bottom of every email. Emails are serviced by Constant Contact