Reasons Mechanical Seals Fail

Fluid Sealing

Reasons Mechanical Seals Fail

By: SEPCO

Mechanical seals prevent pumps from leaking by withstanding the friction caused by the rotating shaft and containing the pressure of the pumping process. The right seals provide reliable operation, more cost savings, less wasted product, and fewer housekeeping issues. However, why do mechanical seals fail?

In many pump systems, a mechanical seal is the first component to fail. They are also the most common cause of pump downtime and account for more pump repair costs than any other part of a pump. Often, however, the seal is not to blame. Other culprits include:

  • Bearing wear
  • Vibration
  • Misalignment
  • Improper seal installation
  • Incorrect seal choice
  • Lubrication contamination

Therefore, teams must install and maintain seals properly to prevent failures. Teams must pinpoint the root causes of each failure. But how do plant and maintenance managers isolate the root cause though?

Why Do Mechanical Seals Fail? Partner with Fluid Sealing Experts to Find out
One option is to have a seal manufacturer perform a seal failure analysis. Some seal manufacturers offer complimentary seal analysis on any seal, not just theirs.

End users simply send their mechanical seal to the manufacturer’s engineering team. If multiple seals need to be analyzed, they may come on-site to perform the root cause analysis. Most reviews can be completed in about two weeks.

With a seal failure analysis, experts deliver a complete diagnosis of why the mechanical seal failed and what actions to take to prevent future failures. The experts who examine the seal can ensure that the ideal seal for the application has been selected. If not, they recommend alternate technologies.

After an analysis, the manufacturing team will also help end users optimize their system conditions and achieve the best possible operation from their assets. Optimizing mechanical seal performance also improves shutdown to shutdown processes. This information, along with alternative proposals as needed, help end users prevent further failures and improve their return on investment.

In summary, a sealing failure analysis:

  • Improves environmental controls
  • Ensures the best installation methods
  • Prevents future equipment failure

    Sepco Reasons Mechanical Seals Fail

    An example of a seal failure analysis form

Why Is a Mechanical Seal Failure Analysis Recommended?
Many problems with a system may be discovered by investigating a failed mechanical seal. In most instances, a seal problem is not the reason for the failure. Something else happened to cause it.

The story of what the seal experienced during operation, before it failed, can be revealed by investigating the failure. An analysis may determine or confirm:

  • If misalignment or other mechanical problems exist in the pump system
  • That the seal is suited for the application
  • If the seal was installed incorrectly
  • If the environmental controls were set up and operated correctly

Eliminating the problems identified by the seal failure analysis may have a huge impact on the system. Several improvements may be realized, including:

  • Optimized operating conditions
  • Reduced downtime
  • Best possible life from the equipment
  • Improved performance
  • Decreased maintenance costs
  • Increased ROI

Why Do Mechanical Seals Fail: Failure Mode Clues
A damaged seal reveals failure clues. Each symptom or clue may mean different things based on:

Sepco Reasons Mechanical Seals FailThe components of a mechanical seal returned for analysis:

1. O-rings
2. Seal sleeve
3. Outboard rotary seal ring and holder
4. Lock collar
5. Gland
6. Gland insert
7. Stationary seat ring
8. Inboard rotary holder and seal ring

For instance, a stationary seal face is cracked, originating from the drive pin slot. Also, sticky residue has adhered to the face. This crack means something different than a stationary seal face with a crack located at a different position and product residue that is fairly clean and not tacky.

Both cases look the same on a simple table listing all the seal damage. However, the failure cause is different. In the first example, the crack was caused by the product attempting to stick the rotary and stationary faces together. This adhesion caused increased torque on the stationary pin. This caused the stationary face to crack.

In the second example, the crack was likely caused by impact. This indicated that the seal was not installed properly. Different symptom combinations reveal multiple failure modes.

Analysis Requirement
In conclusion, to determine the true reason that a seal failed, seal failure analysis is required. Without a diagnosis of the system problem, failure will continue.

Sepco JackAbout the Author

Jack Ferguson is a seal reliability engineer with Sealing Equipment Products Co. Inc. (SEPCO). He is a recent graduate of Clemson University with a degree in mechanical engineering. Ferguson may be reached at jackf@sepco.com.

Related Articles

SEPCO What Is a Lantern Ring

What Is a Lantern Ring?

A lantern ring is a perforated hollow ring located near the center of the stuffing box of a pump. Despite…

Related Whitepapers

Expansion Joint Expertise Improves Industrial Wastewater System Reliability

The majority of industries have wastewater treatment plants. Government agencies and local governments require these facilities to meet pretreatment requirements. Pretreatment rules were enacted to prevent…

How to Decrease Oil Changes with Bearing Isolators [Inforgraphic]

Learning how to decrease oil changes can be time- and money-saving. Oil life can be long if contamination is eliminated, which is easier said than…

Synchronous Machines Are The Optimal Choice For Heavy Industry

TECO-Westinghouse experience assures superior performance and reliability For over a century, Westinghouse has been the pacesetter in the design and production of electric machines for heavy…

Why FLEXXORs Are Designed Differently

J. Hilbert Anderson, President of Coupling Corporation of America, discusses some of the reasons why FLEXXORs are designed differently from all other flexible couplings, and…

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *

Join the #PumpTalk Community


By submitting this form, you are consenting to receive marketing emails from: Empowering Pumps & Equipment, 2205-C 7th Street, Tuscaloosa, AL, 35401, http://www.empoweringpumps.com. You can revoke your consent to receive emails at any time by using the SafeUnsubscribe® link, found at the bottom of every email. Emails are serviced by Constant Contact