Minimizing Soft Foot in the Stationary Machine

soft foot

Minimizing Soft Foot in the Stationary Machine

Anyone who has performed shaft alignment very often knows about soft foot. Simply stated, soft foot is when one or more feet do not rest in a common plane.

If soft foot is not corrected, as hold down bolts are tightened, the motor can move in unintended ways, changing the shaft alignment, and possibly causing distortion of the motor frame. Ignoring soft foot can make alignments less accurate, less repeatable, and take more time than needed. Soft foot can also be a contributor to electrical and mechanical problems in machines.

In most cases, soft foot is thought of as an alignment problem. But soft foot issues in stationary machines can cause some serious problems as well.

• Pumps – A soft foot condition in a pump can cause the pump casing to distort as the pump hold down bolts are being tightened. Many mechanics have witness this occur when a pump turns freely on a work bench, but binds when bolted down. It can cause a rub in the impellor, and can internally misalign the bearings and seal(s).
• Gearboxes – Case distortion caused by soft foot can change the gear tooth clearances, internally misaligning shaft bearings.
• Reciprocating compressors – If the crankcases are not flat, the bearings can bind, connecting rods can drag, and valves can stick.

If one of these types of machines is being rebuilt, or going through a large-scale repair, and soft foot test is recommended. It is also recommended if vibration measurements detect a 2x vibration on the driven machine.

The same procedure used to correct soft foot under a motor is recommended.

AuthorStan Riddle, VibrAlign

Related Articles

Sulzer Cost effective sustainable fuel production

Cost effective sustainable fuel production

Benchmarking Market Report highlights cost-leadership of Sulzer Chemtech BioFlux Process Technology for Renewable Fuels production BioFlux® process technology for renewable fuel…

Related Whitepapers

Expansion Joint Expertise Improves Industrial Wastewater System Reliability

The majority of industries have wastewater treatment plants. Government agencies and local governments require these facilities to meet pretreatment requirements. Pretreatment rules were enacted to prevent…

How to Decrease Oil Changes with Bearing Isolators [Inforgraphic]

Learning how to decrease oil changes can be time- and money-saving. Oil life can be long if contamination is eliminated, which is easier said than…

Synchronous Machines Are The Optimal Choice For Heavy Industry

TECO-Westinghouse experience assures superior performance and reliability For over a century, Westinghouse has been the pacesetter in the design and production of electric machines for heavy…

Why FLEXXORs Are Designed Differently

J. Hilbert Anderson, President of Coupling Corporation of America, discusses some of the reasons why FLEXXORs are designed differently from all other flexible couplings, and…

Comments

One response to “Minimizing Soft Foot in the Stationary Machine”

  1. The Chief says:

    This is why we always have pumps and other equipment re-aligned after being installed or building a new ship or rig. NEVER, NEVER, NEVER just weld or bolt down a base without realigning the equipment. Next be sure that the realignment is done by a professional who is trained in alignment. The next point is be sure the correct coupling is used and the proper installation is done. This is a very good article and point out many important points. I have seen replacement motors and pumps installed when the base was not ground clean and the proper shims were not use so the bolted down equipment does exactly what you are describing. This is another point where the Chief Engineer always take the responsibility for overseeing the work.

Leave a Reply

Your email address will not be published. Required fields are marked *

Join the #PumpTalk Community


By submitting this form, you are consenting to receive marketing emails from: Empowering Pumps & Equipment, 2205-C 7th Street, Tuscaloosa, AL, 35401, http://www.empoweringpumps.com. You can revoke your consent to receive emails at any time by using the SafeUnsubscribe® link, found at the bottom of every email. Emails are serviced by Constant Contact