Pump Station Energy Evaluation for Lynnfield Water District

JKMuir

Pump Station Energy Evaluation for Lynnfield Water District

By: JKMuir

Authors: James F. Finegan, P.E., Superintendent, Lynnfield Water District; Jennifer K. Muir, P.E., JKMuir; Carina L. Hart, Senior Project Engineer, JKMuir; Chelsea Conlon, Project Engineer, JKMuir

The Lynnfield Water District obtained a grant from the Massachusetts Department of Energy Resources (MA DOER). The application-based grant was obtained through MA DOER by James Finegan, the Superintendent of the Lynnfield Water District (District). The Municipal Energy Technical Assistance Grant (META) is intended to provide funding to clean energy projects for municipal entities in Massachusetts. During the application process, the District requested the assistance of JKMuir in developing a proposal for an energy efficiency evaluation of their drinking water pump station. Upon receipt of the grant, JKMuir performed a detailed analysis of the Lynnfield Pump Station. The pump station was evaluated for pump efficiency, operating costs, rate structure, incoming voltage and phase balance, and overall energy use. The intention of the evaluation was to identify energy savings alternatives for the station.

The Lynnfield Water District operates, maintains and controls the distribution system within a portion of the Town of Lynnfield. The District receives metered drinking water from the Massachusetts Water Resource Authority (MWRA).  The District then boosts the pressure of the water to maintain distribution system service and pressure. The distribution system on the MWRA side was recently modified including increasing the pipe diameter of the line feeding the District.  Following these modifications, the suction pressure at the station significantly increased.  This increase has changed the system hydraulics, which may allow smaller pumps to meet the system demands.  Reduced pressure boosting required should reduce energy usage and cost.

The Lynnfield Pump Station contains two horizontal split case centrifugal pumps.  Pump 1 was installed in 1999, has a 50-horse power (hp) motor at 1770 revolutions per minute (rpm), and is rated for 800 gallons per minute (gpm) at 175 feet of head.  Pump 2 was installed in 2008, has a 60 hp motor at 1780 rpm, and is rated for 1,250 gpm at 125 feet of head.

Typical operation is for one pump to run based on water storage tank levels, starting and stopping when the tank reaches low or high set points.  The average hours per day of operation based on pump run hours from 2015 is approximately 7 (6.8 hrs/day).  The variable frequency drives (VFDs) are currently manually adjusted to reduce the speed of the pumps, Pump 1 typically operates at 85% speed and Pump 2 typically operates at 95% speed.  When the pump kicks on it operates at the reduced speed until the shut off tank elevation is reached.  The lead pump is manually switched, by the operators typically once per month.  Two pumps have never historically been operated together, even at times of high demand.  The water storage tanks in the distribution system are the Lynnfield Standpipe 1 and the Lynnfield Standpipe 2. The two tanks are located next to each other and operate at the same hydraulic levels.

JKMuir visited the pump station and collected flow, power quality, and pressure data using portable instrumentation. After analyzing the data, JKMuir presented the Lynnfield Water District with two operational measures (OM) and one energy conservation measure (ECM) that would reduce the pump stations energy usage. A summary of the OMs and ECM and the savings associated with each are presented in the table below.

JKMuir

Table 1. Summary of Operational Measures and Energy Conservation Measures

After the OMs and ECM were presented to the Lynnfield Water District, the facility staff decided to implement OM# 1 in 2016. OM #1 consisted of reducing the operating speed of pump 1 from 85% to 67% and pump 2 from 95% to 75% while increasing the annual hours of operation.

To determine actual energy savings, the energy usage, pump station flow rates, gallons pumped, and hours of operation were tracked before and after the implementation of OM# 1.

The Lynnfield Water District tracked the volume of water pumped by the Lynnfield Pump Station prior to the implementation of OM #1 in 2016 and following the implementation. The figure below compares the Lynnfield Pump Station’s monthly energy usage and gallons pumped in 2015 to the monthly energy usage and gallons pumped in 2016/2017.

JKMuir

Figure 1. Energy Usage and Gallons Pumped in 2015 vs 2016/2017

As presented above, the volume of water pumped in twelve months in 2015 as compared to a similar twelve months in 2016 and 2017 was relatively similar. There was less volume pumped during the winter months and significantly more during the summer months, as expected. However, the energy use was lower following operational changes of the pumps for most of the year on a monthly basis.

In addition to tracking the volume of water pumped each month, the Lynnfield Water District also tracked the monthly hours of operation of the pumps at the pump station. The figure below compares the Lynnfield Pump Station’s monthly energy usage and hours of operation for the twelve months in 2015 to the monthly energy usage and hours of operation in a twelve-month period in 2016/2017.

JKMuir

Figure 2. Energy Usage and Hours Pumped in 2015 vs 2016/2017

As presented above, the operating hours of the pumps increased during 2016 and 2017. However, there was less energy use at the facility.

The table below outlines the increased gallons pumped and annual hours of operation in addition to the reduced energy usage, energy demand and energy cost as a result of the implementation of OM #1.

JKMuir

Table 2. Twelve Month Energy Usage Summary – 2015 vs 2016/2017

After the OM was implemented, the average pump flow rate decreased by approximately 305 gpm and the hours of operation increased by 1,196 hours annually. The pump station pumped 18,488,900 gallons more in 2016/2017 compared to 2015. Although the volume of water pumped and hours of operation of the Lynnfield Pump Station increased, the energy usage was reduced by 14,500 kWh, and the peak demand decreased by 10 kW. Operating the pumps at a lower speed for a longer period of time reduced the energy usage while pumping a larger volume of water. Implementing OM #1 resulted in an annual energy cost savings of approximately $3,600, based on real-time operating data.  The following graph presents the operational data gathered for the pump station prior to and following the implementation of OM #1.

JKMuir

Figure 4.  Lynnfield Water District Pump Station Operational Data

By operating the existing pumps at a speed where the efficiency was higher, the District demonstrated energy savings and demand charge reduction while operating for longer hours and pumping larger volumes of water.

Following the successful implementation of the “no-cost” operation of the existing pumps at the Lynnfield Pump Station the District, with assistance provided by JKMuir, applied for funding through the joint agency Gap II Funding program. The Gap II funding was a collaboration of the Massachusetts Department of Environmental Protection (MA DEP), the MA DOER and the Massachusetts Clean Energy Center (Mass CEC). The application-based Gap II Grant funding is for drinking water or wastewater projects in Massachusetts. In April of 2018, the District was awarded the funding to implement the recommended replacement of their pumps at the booster pump station.

Replacement of the existing pumps, with new pumps sized for the current hydraulics for the system, will provide additional energy and cost savings for the District.

Complete the form below to learn more about how to identify cost effective methodologies that reduce the overall consumption of electricity and greenhouse gas emissions at water, wastewater, and industrial facilities.


Related Articles

Related Whitepapers

Expansion Joint Expertise Improves Industrial Wastewater System Reliability

The majority of industries have wastewater treatment plants. Government agencies and local governments require these facilities to meet pretreatment requirements. Pretreatment rules were enacted to prevent…

How to Decrease Oil Changes with Bearing Isolators [Inforgraphic]

Learning how to decrease oil changes can be time- and money-saving. Oil life can be long if contamination is eliminated, which is easier said than…

Synchronous Machines Are The Optimal Choice For Heavy Industry

TECO-Westinghouse experience assures superior performance and reliability For over a century, Westinghouse has been the pacesetter in the design and production of electric machines for heavy…

Why FLEXXORs Are Designed Differently

J. Hilbert Anderson, President of Coupling Corporation of America, discusses some of the reasons why FLEXXORs are designed differently from all other flexible couplings, and…

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *

Join the #PumpTalk Community


By submitting this form, you are consenting to receive marketing emails from: Empowering Pumps & Equipment, 2205-C 7th Street, Tuscaloosa, AL, 35401, http://www.empoweringpumps.com. You can revoke your consent to receive emails at any time by using the SafeUnsubscribe® link, found at the bottom of every email. Emails are serviced by Constant Contact